home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / generic / 06071csi.gen < prev    next >
Text File  |  1998-06-10  |  9KB  |  201 lines

  1.     SECTION 06071
  2.  
  3.     PRESSURE-TREATED WOOD PRODUCTS
  4. NOTE ** Chemical Specialties, Inc.; preservative and fire-retardant treatments of wood and plywood.
  5. NOTE ** 
  6. NOTE ** This section is based on pressure treatments for wood developed by Chemical Specialties, Inc., located at the following address:
  7. NOTE **    One Woodlawn Green, Suite 250
  8. NOTE **    200 E. Woodlawn Road
  9. NOTE **    Charlotte, NC  28217
  10. NOTE **    Tel: (800) 421-8661
  11. NOTE ** 
  12. NOTE ** Manufacturers using CSI preservatives and fire-retardant treatments to produce top quality pressure-treated wood are located coast-to-coast throughout the United States and Canada.
  13. NOTE ** 
  14. NOTE ** SECTION 06071 - Pressure-Treated Wood Products, Copyright 1997, The Architect's Catalog, Inc.
  15.  
  16. PART 1    GENERAL
  17.  
  18. 1.1    SECTION INCLUDES
  19. NOTE ** Delete items below not required for project.
  20.  
  21.     A.    Preservative treatment of lumber and plywood.
  22.  
  23.     B.    Fire-retardant treatment of lumber and plywood.
  24.  
  25. 1.2    RELATED SECTIONS
  26. NOTE ** Delete any sections below not relevant to this project; add others as required.
  27.  
  28.     A.    Section 06100 - Rough Carpentry.
  29.  
  30.     B.    Section 06200 - Finish Carpentry.
  31.  
  32. 1.3    REFERENCES
  33. NOTE ** Delete references from the list below that are not actually required by the text of the edited section.
  34.  
  35.     A.    APA A400 - Permanent Wood Foundation Guide to Design and Construction; American Plywood Association.
  36.  
  37.     B.    ASTM A 153/A 153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron And Steel Hardware.
  38.  
  39.     C.    AWPA C2 - Lumber, Timber, Bridge Ties and Mine Ties -- Preservative Treatment by Pressure Processes;  American Wood-Preservers' Association.
  40.  
  41.     D.    AWPA C20 - Structural Lumber -- Fire-Retardant Treatment by Pressure Processes;  American Wood-Preservers' Association.
  42.  
  43.     E.    AWPA C22 - Lumber and Plywood for Permanent Wood Foundations -- Preservative Treatment by Pressure Processes; American Wood-Preservers' Association.
  44.  
  45.     F.    AWPA C27 - Plywood -- Fire-Retardant Treatment by Pressure Processes; American Wood-Preservers' Association.
  46.  
  47.     G.    NFPA Permanent Wood Foundation System: Design, Fabrication, Installation Manual; National Forest Products Association.
  48.  
  49. 1.4    SUBMITTALS
  50.  
  51.     A.    Submit under provisions of Section 01300.
  52.  
  53.     B.    Product Data:  Treating plant's instructions for use, including requirements for storage, cutting, and finishing.
  54.  
  55.     C.    Preservative Treatment Certification:  Treating plant's certification of compliance with specified standards, process employed, and preservative retention values.
  56. NOTE ** Delete paragraph above or below if treatment type not required.
  57.  
  58.     D.    Fire-Retardant Treatment Certification:  Treating plant's certification of compliance with specified requirements.
  59. NOTE ** Delete the folowing article if fire-retardant treatment not required for project.
  60.  
  61. 1.5    QUALITY ASSURANCE
  62.  
  63.     A.    Fire-Retardant Treatment:  Mark each piece of plywood and lumber to show compliance with specified standards.
  64.  
  65. 1.6    DELIVERY, STORAGE, AND HANDLING
  66.  
  67.     A.    Protect wood products against moisture and dimensional changes, in accordance with instructions from treating plant.
  68.  
  69. 1.7    WARRANTY
  70.  
  71.     A.    Manufacturer's Warranty:  Provide manufacturer's standard 20-year limited warranty for fire-retardant treated wood.
  72.  
  73.     B.    Manufacturer's Warranty:  Provide manufacturer's standard 50-year limited warranty for pressure-treated wood.
  74. NOTE ** Retain paragraph above for ULTRAWOOD(R) treatment.  Retain paragraph below for SUPATIMBER(R), DESIGNWOOD(R) SUPATIMBER, and ACQ(R) PRESERVE(R).
  75.  
  76.     C.    Manufacturer's Warranty:  Provide manufacturer's standard lifetime warranty for pressure treated wood.
  77.  
  78. PART 2    PRODUCTS
  79.  
  80. 2.1    MANUFACTURERS
  81.  
  82.     A.    Provide wood treatment by or under license from Chemical Specialties, Inc., One Woodlawn Green, Suite 250, 200 E. Woodlawn Road, Charlotte, NC  28217. ASD. Tel: (800) 421-8661.
  83.  
  84.     B.    Requests for substitutions will be considered in accordance with provisions of Section 01600.
  85. NOTE ** Delete paragraph above or below;  coordinate with Division 1 requirements.
  86.  
  87.     C.    Substitutions:  Not permitted.
  88.  
  89. 2.2    MATERIALS
  90.  
  91.     A.    Dimension Lumber:  As specified in Section 06100.
  92.  
  93.     B.    Structural Plywood:  As specified in Section 06100.
  94.  
  95.     C.    Finish Lumber and Plywood:  As specified in Section 06200.
  96.  
  97.     D.    Fasteners:  For treated wood and where wood is in ground contact, subject to high relative humidity, or exposed to weather, provide steel fasteners with hot-dip zinc coating per ASTM A 153/A 153M.
  98.  
  99. 2.3    PRESSURE TREATMENT OF WOOD
  100. NOTE ** CSI offers the following preservative treatments:
  101. NOTE ** 
  102. NOTE ** ACQ(R) Preserve(R):  Environmentally designed treatment that protects against rot, decay, and termite damage.  It is free of arsenic and chromium and does not require special handling of refuse.
  103. NOTE ** 
  104. NOTE ** UltraWood(R):  Includes water repellent in preservative treatment to fight checking, cracking, spitting, and warping.  50-year performance warranty.
  105. NOTE ** 
  106. NOTE ** SupaTimber(R):  Clean and odor-free pressure treatment contains waterborne arsenical preservatives; requires some precautions in use and handling.
  107. NOTE ** 
  108. NOTE ** DesignWood(R) SupaTimber:  Prefinished preservative treatment includes redwood color to eliminate the need for applying paints or stains.
  109.  
  110.     A.    Preservative Treatment for Above Ground Use:
  111.         1.    Treatment:  ACQ(R) Preserve(R).
  112.         2.    Treatment:  UltraWood(R).
  113.         3.    Treatment:  SupaTimber(R).
  114.         4.    Treatment:  DesignWood(R) SupaTimber(R).
  115.         5.    Use 0.25 lb/cu ft (4.0 kg/cu m) retention.
  116.         6.    Kiln dry after treatment to 19 percent maximum moisture content for lumber and 18 percent for plywood.
  117.         7.    Treat wood in the following locations:
  118.             a.    In contact with roofing, flashing, or waterproofing.
  119.             b.    In contact with masonry or concrete.
  120.             c.    Within 18 inches (450 mm) of grade.
  121.             d.    Exposed to weather.
  122.             e.    Other locations indicated.
  123.  
  124.     B.    Preservative Treatment, Ground and Fresh Water Contact:
  125.         1.    Treatment:  ACQ(R) Preserve(R).
  126.         2.    Treatment:  UltraWood(R).
  127.         3.    Treatment:  SupaTimber(R).
  128.         4.    Treatment:  DesignWood(R) SupaTimber(R).
  129.         5.    Use 0.40 lb/cu ft (6.4 kg/cu m) retention.
  130. NOTE ** Use 0.60lb/cu ft (9.6 kg/cu m) retention for utility poles.
  131. NOTE ** Use 0.80 to 1.0 lb/cu ft (12.8 to 16.0 kg/cu m) retention for pilings, per AWPA Standards.
  132. NOTE ** Use 2.50 lbs/cu ft (40.0 kg/cu m) for salt water marine pilings.
  133.         6.    Kiln dry after treatment to 19 percent maximum moisture content for lumber and 18 percent for plywood.
  134.         7.    Treat wood in the following locations:
  135.             a.    In contact with ground.
  136.             b.    In contact with fresh water.
  137.             c.    Used as posts, landscaping timbers, retaining walls, piers, or docks.
  138.  
  139.     C.    Preservative Treatment for Wood Foundation Systems:
  140.         1.    Pressure-treat softwood lumber, timber, and plywood for wood foundation systems with waterborne preservatives to comply with AWPA C22-96.
  141.         2.    Treatment:  ACQ(R) Preserve(R).
  142.         3.    Treatment:  UltraWood(R).
  143.         4.    Treatment:  SupaTimber(R).
  144.         5.    Treatment:  DesignWood(R) SupaTimber(R).
  145.         6.    Use 0.60 lb/cu ft (9.6 kg/cu m) retention.
  146.  
  147.     D.    Fire-Retardant Treatment:
  148.         1.    Lumber:  Comply with AWPA C20.
  149.         2.    Plywood:  Comply with AWPA C27, Type A.
  150. NOTE ** D-Blaze(R) fire-retardant treatment can be used in a variety of interior applications where the humidity is not expected to exceed 95 percent for prolonged periods and where the wood is not exposed directly to weather.
  151. NOTE ** 
  152. NOTE ** D-Blaze is approved under the following codes and standards:
  153. NOTE **    BOCA
  154. NOTE **    ICBO ERS180
  155. NOTE **    SBCCI
  156. NOTE **    MIL-L-191040E
  157. NOTE **    NFPA 255
  158. NOTE **    UL 723
  159. NOTE **    New York City Building Code
  160. NOTE **    Los Angeles Building Code
  161. NOTE **    Report RR 24502
  162.         3.    Surface Burning Characteristics:  UL FRS rating; flame spread and smoke developed ratings of 25 or less in a test of 30 minutes' duration.
  163.         4.    Treatment:  D-Blaze(R).
  164.         5.    Treat wood used for the following applications:
  165.             a.    Roof and floor trusses.
  166.             b.    Roof decks and sheathing.
  167.             c.    Subflooring.
  168.             d.    Beams and purlins.
  169.             e.    Millwork and trim.
  170.  
  171. PART 3    EXECUTION
  172.  
  173. 3.1    INSTALLATION
  174.  
  175.     A.    Framing and Sheathing:  Comply with installation requirements in Section 06100.
  176.  
  177.     B.    Millwork and Trim:  Comply with installation requirements in Section 06200.
  178.  
  179.     C.    Fire-Retardant Treated Wood:  End cuts and drilling are permitted.  Do not rip or mill lumber or plywood after fire-retardant treatment.
  180.  
  181.     D.    Wood Foundation System:  Install in accordance with the following:
  182.         1.    NFPA "Permanent Wood Foundation System."
  183.         2.    NFPA Technical Report No. 7.
  184.         3.    APA Form A400.
  185.  
  186.  
  187.     END OF SECTION
  188. ??
  189.  
  190.  
  191.  
  192.  
  193.  
  194.  
  195.  
  196.  
  197.  
  198.     06071-1